Fan RV -C

Centrifugal fan with closed fan wheel that is used for source extaction for air-pollulant and chip making work processes.

Radial fan with closed fan wheel mounted in welded steel cabinet and directly coupled motor. Transported air may not contain adhestive or sticky fumes or dust.

Fan_RVC_35_GramCleanAir
SLIDE510X339_0065
SLIDE510X339_0066
SLIDE510X339_0074
Product Features
  • Fully tested fan
  • Max. pressure: 5,800Pa.
  • Max. air volume: 32,500m³/h
  • Max. dust volume: 5g/m³, non-sticky
  • Max. particle size: 5x5x5mm, non-sticky
  • Temperature extracted air: max. 60°C
  • Ambient temperature: max. 40°C
Part 1
Item numberModel typeFan
type
Achieved
efficiency
VSDMeasurement
category
Efficiency
type
Efficiency classification
(η at BEP)
03 400 700RV 35/1-C2Backward curved centrifugal fan53,8NODTOTAL67
03 401 700RV 35/2-C2Backward curved centrifugal fan56,6NODTOTAL67
03 402 000RV 35/3-C2Backward curved centrifugal fan61,3NODTOTAL67
03 406 400RV 45-C2Backward curved centrifugal fan65,1NODTOTAL67
03 410 400RV 50-C2Backward curved centrifugal fan68,7NODTOTAL67
03 415 000RV 60-C2Backward curved centrifugal fan61,9NODTOTAL67
03 417 300RV 70-C2Backward curved centrifugal fan65,8NODTOTAL67
03 418 000RV 80-C2Backward curved centrifugal fan77,6NODTOTAL67
03 418 500RV 85-C2Backward curved centrifugal fan69,8NODTOTAL67
03 419 000RV 90-C2Backward curved centrifugal fan76,4NODTOTAL67
03 420 000RV 35-C4Backward curved centrifugal fan58,2NODTOTAL67
03 422 400RV 50-C4Backward curved centrifugal fan57,6NODTOTAL67
03 423 000RV 60-C4Backward curved centrifugal fan62,2NODTOTAL67
03 425 300RV 70-C4Backward curved centrifugal fan59,8NODTOTAL67
03 426 000RV 80-C4Backward curved centrifugal fan68,8NODTOTAL67
03 427 000RV 85-C4Backward curved centrifugal fan69,8NODTOTAL67
03 428 000RV 90-C4Backward curved centrifugal fan67,3NODTOTAL67
Part 2
Item numberModel typeMotor input power
(kW)
Volume flow
(m³/h)
Vacuum
Pa (Ps)
Special
characteristics
rpmPressure ratioDisassemblyEnvironmental
impact
03 400 700RV 35/1-C23,4515903900NO29011,04B.4B.4
03 401 700RV 35/2-C24,4021563780NO29251,04B.4B.4
03 402 000RV 35/3-C25,0427004085NO29451,04B.4B.4
03 406 400RV 45-C28,0854323380NO29331,03B.4B.4
03 410 400RV 50-C29,8465613610NO29421,04B.4B.4
03 415 000RV 60-C215,53113052910NO29441,03B.4B.4
03 417 300RV 70-C220,41122703850NO29551,04B.4B.4
03 418 000RV 80-C227,14135575640NO29771,06B.4B.4
03 418 500RV 85-C232,44191674220NO29681,04B.4B.4
03 419 000RV 90-C235,54187065080NO29811,05B.4B.4
03 420 000RV 35-C40,711444960NO14461,01B.4B.4
03 422 400RV 50-C41,403708750NO14491,01B.4B.4
03 423 000RV 60-C42,0343471005NO14761,01B.4B.4
03 425 300RV 70-C42,324945970NO14701,01B.4B.4
03 426 000RV 80-C43,7083711060NO14651,01B.4B.4
03 427 000RV 85-C44,3275331350NO14811,01B.4B.4
03 428 000RV 90-C44,8581701380NO14791,01B.4B.4
Remarks: The above fans are not for DC operation. They are not supplied with loose essential components. σBEP>0.12
Further data
  • Radial fan type RV-C is constructed with closed fan wheel, mounted in a welded steel cabinet and with direct coupled motor.
  • Closed wheel with wheel with backward straight, self-cleaning blades
  • Static/dynamically balanced according to ISO 14694 (BV3 G 6.3)
  • Fan housing can be mounted in various outlet positions.
  • Powder enamelled for indoor mounting.
  • Galvanized is recommended at outdoor mounting.
  • Motor IE3, B3 flange motor (from 11.0kW and up the motor is delivered incl. bimetallic sensor).

Constructed and tested according to:

  • Machine Directive 2006/42/EU
  • Electromagnetic Compatibility (EMC) Directive 2004/108/EU
  • Low Voltage (LVD) Directive 2014/35/EU
  • Harmonized standards: EN 12100, EN 60204-1, EN ISO 13857, ISO 12499
  • Further standards: ISO 3746, ISO 5801
  • As well as: EU Regulation No. 2024/1834 (the Ecodesign Regulation for fans)

Further is available:

  • Pressure guard
  • Sound enclosure
  • Construction adapted for 60Hz operation
  • Mounting fittings
  • Vibrations absorbers
  • Safety grid
  • FLEX flexible connections
  • Explosion-protected construction for application in ATEX-zones
  • Hot-galvanized powder enamelled version of the fan
  • Motor starter Y-D
  • Frequency converter
Documents